22-9058 v2.1
Welcome
PCPanel IP Cent. Mon. with IP
Ref. Topics
3
1.2.2 Concept: PC-to-Panel Connection with IP
A PCpanel connection with IP provides an alternative to a direct connection or dial-up
modems, and utilizes existing network cabling (10BaseT / RJ45). This feature can be used in
conjunction with "Central Monitoring with IP" (SIP Reporting), or on its own.
LAN/WAN
ISM/AFx
Main
Panel
Director Software
10BaseT / RJ45
Up to 30 panels
per connection
More
Panels
To sensors,
modules,
etc.
(Host)
IP
Interface
)
To sensors,
modules, etc.
(single PC, or client/server)
(Optional)
(
Shared with SIP
reporting, if applicable.
1.2.3 Concept: Central Monitoring with IP (SIP Reporting)
Where a monitoring facility is on a shared LAN/WAN network with the sites it will be
monitoring, the link can be made through the network as an alternative (or in addition to) dial-
up reporting (Bell 103, 300 baud). This feature can be used in conjunction with a "PCPanel
with IP" connection, or on its own.
LAN/WAN
ISM/AFx
Main
Panel
Monitoring Facility
10BaseT / RJ45
Up to 30 panels
per connection
More
Panels
To sensors,
modules,
etc.
IP
Module
)
To sensors,
modules, etc.
IP Receiver
Software
(Optional)
(
Shared with PCPanel
via IP, if applicable.
Automation Software
(e.g., MAS)
IP
Slave
NOTE: If IP Communications is desired for BOTH the Director Software AND the Security IP
Monitoring Facility, two (2) communication cables will be required.
Please see general cable specifications, Sect. 2.2 and Master Wiring References, Sect 4.2.