32 MONITOR ISM™/AFx™ IP Connectivity Guide 22-9058 v2.1
Master Wiring References
A IP Interface Module board can consume up to 250 mA. As such, it may require the addition
of a 12V power supply. The main panel can supply a total of 750 mA for all loads (Module
Bus/modules, and aux. power connection). Install a 12 VDC power supply as necessary.
Arrangements must be made with the customer to supply the 10BaseT cable connection from
their network to the IP Interface board’s network connector.
When IP is used for SIP by itself (no Director comms) and separate power supplies or, each
motherboard’s auxiliary power is used to separately power interface/slave boards, the SIP
Ground connection of each IP board must be common.
TB2
TB1
1
2
3
1
2
3
SIP RS485 A
SIP RS485 B
SIP Ground
Dir RS485 A
Dir RS485 B
Dir Ground
IP Interface Module P/N 650-9058
Black
( ) Neg. GND
Red
(+) 12VDC
Orange
RS232 RX
Yellow
RS485 B
Blue
RS232 TX
Green
RS485 A
Main Panel # 1
motherboard terminal
connectors on right
side of board.
(+)
(+)
(-)
(-)
TB2
12
Main Panel
motherboard
auxiliary 12VDC
(750mA max.) left
side of board.
NOTE: If the IP Interface Module is powered from the motherboard, this ground connection is not necessary.
Only use this connection when the IP Interface is powered by a separate power supply.
1432
5
0V
B485
A485
GND/GND
CTS/RTS
RTS/CTS
DSR/DTR
DTR/DSR
TX/TX
RI/RI
CD/CD
TB16
1432 312
RX/RX
Yellow
Green
(Yellow)
(Green)
(Black)
Black
1432
5
0V
B485
A485
GND/GND
CTS/RTS
RTS/CTS
DSR/DTR
DTR/DSR
TX/TX
RI/RI
CD/CD
TB16
1432 312
RX/RX
Yellow
Green
Black
Yellow
Green
Black
When installing the IP Interface
Module, remove any applicable
existing terminal blocks and replace
with the supplied pre-wired ones as
indicated.
Recommended interconnecting comms cable:
Module Bus, 4 conductor shielded P/N 120-3401.
The comms cable ground shield is connected
to the first motherboard waterpipe ground,TB5.
1432
5
0V
B485
A485
GND/GND
CTS/RTS
RTS/CTS
DSR/DTR
DTR/DSR
TX/TX
RI/RI
CD/CD
TB16
1432 312
RX/RX
Main Panel # 2
motherboard
Main Panel # 3
motherboard
The comms cable ground shields
are connected together, running
through additional panels but, not
terminated in any of them.
Not Used
Not Used
TB15
TB14
TB15
TB14
TB15
TB14
Director Communications Only (figure 3)
Vista de página 35