42 MONITOR ISM™/AFx™ IP Connectivity Guide
22-9058 v2.1
( - ): Initialization error. If the dash appears as an
"A", you have a digital account ID mismatch between
the panel and the IP receiver software ("Digital ID"
connect mode). If this appears as an "S", you have a
serial number mismatch between the panel and the IP
receiver software ("Serial Number" connect mode). If
this appears as an "L", you have an SIP Address
mismatch between the panel and the IP receiver
software ("SIP Address" connect mode). If this
appears as an "M", contact your support rep.
t x: Represents the polling timeout code ‘t’
before detecting SIP failure after ‘x’ time
delay.
x = Delay Cycle
0 10 seconds 0 – 2
1 15 seconds 3 – 5
2 30 seconds 6 – 10
3 45 seconds 11 – 15
4 60 seconds 16 – 20
5 90 seconds 21 – 30
6 2 minutes 31 – 40
7 3 minutes 41 – 60
8 8 minutes > 60
3 X the poll rate set in the IP Interface Module
Config Program / SIP programming screen /
Advanced Setup / Cycle.
E.g. Timeout in the SIP program screen =
3(00). t x in the LCD keypad Data screen =
t 3 – the panel will detect SIP failure and
switch to dialler back-up (must be set in
Director Account Configurations / System /
Communication. See Sect 3.4, NOTE2) after
45 seconds of no polling.
Vista de página 45