26 MONITOR ISM™/AFx™ IP Connectivity Guide 22-9058 v2.1
3.5.4 SIP Receiver Software: Configuration Settings
When you start up the IP receiver software, click on the configuration tab at the bottom. Each
panel IP-connection to be 'polled' is associated with one row on the screen. The top half of the
screen contains settings for the automation software that must be set appropriately, and the
row for each IP connection must be set up as well. Refer to the descriptions below while
making your selections.
Top half of the screen (setting for the automation software):
• Active: ( ) = SIP monitoring is turned on
(this selection is required).
• UDP Port
: The port number used on this PC
for SIP Communications. Typically 24833.
• Serial Port
: The PC's serial port used to
communicate with the automation software.
• Prefix
: Leave as “S011[#”. This is the prefix
to be added to alarm messages.
Reference:
“S” = SIA,
“01” = receiver number 1,
“1” = line card number 1,
“[#” = standard SIA prefix.
• Line Trouble
: SIA code to be generated if
the SIP connection fails. Typically "LT"
(the
same as for a modem connection; can be
changed to other valid SIA value)
.
• Heartbeat
: A standard signal that goes to
the automation software to show it that the
receiver is active. If the heartbeat signal
fails, the automation software should inform
the operator right away.
WARNING:
double check this setting to
make sure it is: 1011(11 spaces
) @ (4
spaces) /020. The proper number of spaces
between characters is very important.
• Baud
: The speed used for communications
with the automation software. Normally
1200.
• Separator
: Leave as N (new event SIA block).
• Line Restore
: SIA code to be generated
when SIP communications restores.
Typically "LR"
(the same as for a modem
connection; can be changed to other valid
SIA value).
--------------------
• Mode
: The communications format used
with the automation software. Normally,
7,E,1 (7 data bits, even parity, 1 stop bit).
• Suffix
: Leave as “]\020”.
• Substitution
: “UX5” SIA code that will be
generated if a substitution of panel
equipment is detected.
• Ticks
: How often a heartbeat signal is sent
to the automation software. Typically every
30 seconds.
--------------------
• Timeout
: The maximum time this program
will wait for an acknowledge signal from the
automation software. Typically, 2000 milli-
seconds.
• ACK
: Leave as “/006”. Standard ack signal.
• Sub’ Restore
: “UX6” SIA code that is
always generated immediately after a
substitution detection.
--------------------
• Retries
: The maximum number of times this
software will attempt to send a message to
the automation software. Typically 3.
• NAK
: Leave as “/021”. Standard nak signal.
Comentários a estes Manuais