34 MONITOR ISM™/AFx™ IP Connectivity Guide 22-9058 v2.1
TB2
TB1
1
2
3
1
2
3
SIP RS485 A
SIP RS485 B
SIP Ground
Dir RS485 A
Dir RS485 B
Dir Ground
IP Interface Module P/N 650-9058
Black
( ) Neg. GND
Red
(+) 12VDC
Orange
RS232 RX
Yellow
RS485 B
Blue
RS232 TX
Green
RS485 A
1432
5 312
0V
B485
A485
GND/GND
CTS/RTS
RTS/CTS
DSR/DTR
DTR/DSR
TX/TX
RI/RI
CD/CD
TB16
(+)
(+)
(-)
(-)
TB2
12
Main Panel
motherboard
auxiliary 12VDC
(750mA max.) left
side of board.
NOTE: If the IP Interface Module is powered from the motherboard, this ground connection is not necessary.
Only use this connection when the IP Interface is powered by a separate power supply.
1
2
3
SIP Ground
Green
RS485 A
Blue
RS232 TX
Yellow
RS485 B
Orange
RS232 RX
Red
(+) 12VDC
Black
( ) Neg. GND
Slave Board
Wire Connectors
P/N 650-9057
1
2
3
SIP Ground
Green
RS485 A
Blue
RS232 TX
Yellow RS485 B
Orange
RS232 RX
Red
(+) 12VDC
Black
( ) Neg. GND
Slave Board
Wire Connectors
P/N 650-9057
RX/RX
1432
14321432
Module
Bus
Module
Bus
Module
Bus
TB13TB12TB11
1432 5
0V
B485
A485
GND/GND
CTS/RTS
RTS/CTS
DSR/DTR
DTR/DSR
TX/TX
RI/RI
CD/CD
TB16
1432 312
RX/RX
Yellow
Green
(Yellow)
(Green)
(Black)
(Yellow)
(Green)
(Black)
(Black)
Green
Yellow
“B” connector
(P/N 496-1700)
Black
1432
5
0V
B485
A485
GND/GND
CTS/RTS
RTS/CTS
DSR/DTR
DTR/DSR
TX/TX
RI/RI
CD/CD
TB16
1432 312
RX/RX
Yellow
Green
Black
Y
e
l
l
o
w
G
r
e
e
n
G
r
e
e
n
Y
e
l
l
o
w
Not Used
Not Used
Yellow
Green
Black
(Black)
When installing the IP Interface
Module, remove any applicable
existing terminal blocks and replace
with the supplied pre-wired ones as
indicated.
Motherboard
auxiliary power
or power supply.
Motherboard
auxiliary power
or power supply.
Grounds must be
interconnected
between boards if
SIP is used
alone.
Recommended interconnecting comms cable:
Module Bus 4 conductor shielded, P/N 120-
3401. Use 2 cables to accommodate 5 wires
needed if doing both Director and Security IP
Receiver communications.
The comms cable’s ground shields are
connected to the first motherboard waterpipe
ground,TB5.
The comms cables
ground shields are
connected together,
running through
additional panels
but, not terminated
in any of them.
Combined Director and Security IP (SIP) Receiver Communications (figure 5)
Main Panel # 1
motherboard terminal
connectors on right
side of board.
Main
Panel # 2
motherboard
Main
Panel # 3
motherboard
Vista de página 37