10 MONITOR ISM™/AFx™ IP Connectivity Guide
22-9058 v2.1
Identification
New Name E.g. location of IP board (30 -alpha/numeric-characters maximum).
New Password
Enter a maximum 8-alpha/numeric-character password that will restrict access to the
config screens in the future. Be sure to mark this password down in a secure place as it will be requested
each time the IP Module configurations are accessed.
IP
IP Address should be the one assigned for the module at its final destination.
Net Mask
If it is not needed, enter “0.0.0.0”.
Gateway
If it is not needed, enter “0.0.0.0”.
Security (check boxes)
Disable Telnet Check this box if denying access to the config programming by Telnet.
Disable Password
Check this box if a password to access the configs is not required.
Disable Remote Configuration
Check this box to disable remotely connecting to this IP board’s
configuration. This will not disable using “Discovery Mode”.
Disable File Download
Check this box to deny firmware upgrades to this IP board.
Press the “Send To” button on the top tool bar.
The activity bar at the bottom of the config screen will change from Online to “Configuration download
complete”.
The IP Host board has now been programmed. Press the Disconnect button and return to the
Connection screen to view the new settings instead of e.g. question marks.
The unit can be pinged again with a reply like the following:
Other IP Configuration Program Tool Bar Buttons
Follow the on screen instructions after pressing a button.
Abort
Cancel “Connect” attempt if it appears an IP Interface Module is not responding.
Disconnect
on line communications between the config program and an IP board.
Upgrade
IP Interface Module’s firmware version to a newer one.
Force
If the IP board whose firmware is being upgraded with a previous version (for what ever
reason) replies after the upgrade attempt that the version is not current, this button can be pushed to
force the upgrade.
Save
- a current config to a template file.
Load
- a saved template file to program an IP board.
Defaults
Return configured screens back to their defaults EXCEPT the IP address, Subnet Mask and
Default Gateway settings will remain the same.
Help
Display IP Config Program version number.
Connecting to a Programmed IP Board
To connect to an IP Interface Module that has already been configured, click on the “Connect
remotely…” selection in the Connection screen.
Enter the board’s IP address and applicable password and then press the “Connect” button.
Debug Tab
Is for Manufacturer’s Use Only.