500-9041 v4.1
Welcome Report
Control
Admin Sys Config Tech-Ref
51
tour, and setting the allowable time-
range for the guard to arrive from the
previous station / checkpoint (in
minutes);
This is the same as right-clicking the centre
portion of the form and selecting "
Add
New
".
Multi-
Panel
Systems: Items to be added to
a guard-tour can be set to display either as
a single list, or on a panel-by-panel basis.
For details on these choices, refer to "Other
Desktop Choices".
-[Remove]:
Click this to remove a
selected checkpoint (door or input-
point) from the guard-tour;
- [Edit]:
Click this to allow changing an
existing checkpoint:
+
Selecting a different door or guard-tour
input-point, and/or;
+
Changing the allowable time-range for
the guard to access this checkpoint;
-[Up]:
Moves a selected checkpoint up to an
earlier position in the guard-tour, while leaving
the time-range values as-is;
-[Down]:
Moves a selected checkpoint down to a
later position in the guard-tour, while leaving the
time-range values as-is.
After changing the position of any stations (checkpoints)
in a guard-tour, be sure to always re-check the min/max
time values. (To change the times, select the item in
the guard-tour, click
[Edit]
, and make your desired
changes, clicking
[Ok]
when finished.)
- Doors and Input Points
(top of the form)
:
This
is where you select the specific door or input-
point pertaining to the guard-tour station being
added or changed;
To be available here, the specific doors and input-
points must already be defined in the system. As well,
guard tour inputs must be set as a "Custom Point
Type" with the "Preprocess" set as "Guard Tour" (and
the "Level" set as "24 hours"). For details, refer to:
"Doors, Readers, and Related Settings",
"Input Points—Custom Point Types", and
"Input Points—Monitored Sensors", as applicable.
- Minimum Time:
The minimum allowable time
for the guard to reach this station (from the
previous one);
- Maximum Time:
The maximum allowable time
for the guard to reach this station (from the
previous one);
Note:
For the 1
st
station (i.e., the "Start Point"
selected under "Guard Tour Monitor"), the time is from
when the guard tour is activated (i.e., when the guard
tour is 'added' to the Guard-Tour
monitor
screen).
Guard Tours
Guard Tours [Select Station]
(or
[Edit]
)