Suite-Security Keypads
Suite-security keypad modules provide
security and monitoring features for individual
apartments facilities (up to 60 per main panel).
There are two types of suite-security keypads:
•
8-zone
: This version supports 8 monitored
sensors (inputs), 2 programmable outputs, and 3
'panic keys'.
•
2-zone
: The more affordable 2-zone units support
2 monitored sensors/inputs, one panic key, and
one programmable output.
Two-zone units require panel firmware V3.2 or higher.
With 8-zone units, panel firmware
v2.7
or
V3.2
(or
higher) is recommended.
Suite-security keypads can be mixed with other
modules if desired (the suite capacity is reduced by
5
for each system LCD keypad, and each other
expansion / application module added.
Support for suite-security keypads requires a 'feature-
set' selection of
5
or higher (via Enterprise software
licensing).
For details, refer to "Account-Wide Panel Settings", and
"Software Activation and Licensing".
Notice:
Suite-security keypads are
not
associated with
any system 'Areas' or related schedules or settings. As
well, these units are
NOT
associated with the module
screen. All settings that affect suite-security-keypad
operation are defined here.
Accessing this Topic
(Multi-
Account
Systems: Click
[Account Folders]
in
the 'tree', and locate and double-click the desired
account.)
Select
Suite Security
from the MyTools bar,
or
click your site/account button in the tree,
open "Configuration" (
+
), and select
Suite
Security
.
(Under the specific panel group and panel-
-if listed in the 'tree'.)
Panel Groups and Panels: The 'tree' can be set to
show configuration topics in a single list (logical tree
view), or on a panel-by-panel basis (best for multi-panel
systems). For details, refer to "Other Desktop
Choices".
Adding a New Suite-Security Keypad
Access "Configuration Suite Security" as
described previously, and use the
Grid
/
Form
toolbar-button to select your preferred 'view'.
Forms view: Details for one suite/facility at a time;
Grid View: All defined suites in a list.
Now, click
[+]
at the bottom of the form, or
right-click the form, and select
Add New
from
the pop-up menu.
Alternative: You can also select a blank/grey item from
the list (Forms view: bottom of the window). If no grey
ones are listed (or the form is blank), click
Filter
on the
toolbar, and re-check the listing.
Now, refer to the selection-descriptions for this
screen while entering and/or selecting your
desired settings.
Tip:
The 'Standard' tab typically includes all settings
required for basic operation (and additional tabs contain
more advanced features).
Suite-Security Keypads and Related Settings
If you change any value for a suite-security keypad, this will cause that unit to be reset to its default / scheduled
state
and arming level
(this allows configuration updates to be managed properly). As such, configuration changes
to active units should be done only by arrangement with the occupant.