8 Zone Keypad
Operation
2 Zone Keypad
Operation
6 MONITOR ISM™/AFx™ Multi-Tenant Security System User Guide 22-9050 v1.3
2 3
5 6
8 9
0
12345
678
S
T
f
4

7
1
X
!
Turning the System On Remotely If you left and forgot to turn the system on, it can be remotely armed
by the building security dept. Contact the guard, identify your suite and ask the guard to turn the system
on.
Verify User
If you think you have caused a false alarm (keypad tones continuously) you can notify the
Security Dept. that YOU are on the premises before contacting them by phone.
If armed, turn system off with PIN #.
Then, send Verify Code:
Press then and your PIN again.
If armed, turn system off with PIN #.
Then, send Verify Code:
Press then and your PIN again.
Bypass a Sensor Zone
NOTE: An entry/exit sensor zone, example: main entrance door cannot be bypassed.
Press then then the
Sensor Zone number 1 – 8 and your PIN.
Only one point can be bypassed at a time. Repeat
the same sequence to remove the zone’s bypass.
A Master or Resident authority level User turning
the system OFF will automatically remove a
bypass.
Press then then the
Sensor Zone number 1 or 2 and your PIN.
Only one point can be bypassed at a time. Repeat
the same sequence to remove the zone’s bypass.
A Master or Resident authority level User turning
the system OFF will automatically remove a
bypass.
Chime Keypad warning tone that entry door has been opened.
Press then turns chime on.
Press then turns chime off.
Press then once to turn
feature on.
Repeat to turn off.
System Test All keypad lights, sounder turn on for 5 seconds.
Press then then PIN.
Press to stop sooner.
Press then then then
PIN.
Press to stop sooner.
Walk Test Protection points can be tested with this command. After entering the command at the keypad,
trip the protection points. Example: open front door and close it, the light marked 1 turns on solid. This
means protection point # 1 is working OK. Do the same to test the next point, example: light marked # 2 is
a motion detector. Trip it and let it reset. Light # 2 turns on solid, etc.
Press then then PIN.
Test will last 5 minutes or press to stop.
Press then then then
PIN.
Test will last 5 minutes or press to stop.
4
X
#
6
7
!
8
4
8
6
5
7
2
7
1
X
#